Overview
Original source dataAn authorization bypass vulnerability in the FileMaker Server Web Publishing Engine allowed requests containing an extended privilege header to bypass the disabled Custom Web Publishing with XML setting and access the XML Web Publishing interface. This vulnerability is addressed in FileMaker Server version 26.0.3.
Affected products and scope
- Claris FileMaker Server: releases less than
26.0.3are marked affected. - The record identifies FileMaker Server
26.0.3as addressing the vulnerability. - The status of parallel release branches or releases not directly classified by the record remains subject to confirmation from Claris guidance.
Technical details
The flaw is in the Web Publishing Engine of Claris FileMaker Server and is classified as an authorization bypass through user-controlled input. A request containing an extended privilege header can bypass the disabled Custom Web Publishing with XML setting and reach the XML Web Publishing interface. The supplied assessment indicates a network-reachable path that requires no authentication or user interaction and has low attack complexity. The record does not disclose the exact header syntax, internal validation logic, or the specific XML operations available after access.
Exploitability
The vulnerability is reachable over the network through requests that require no authentication or user interaction; the supplied assessment indicates low attack complexity. The record does not identify additional deployment requirements beyond a Web Publishing Engine that can receive the request. The supplied public_exploit field is false, and the returned CISA enrichment marks exploitation as none. No specific campaign, victim, payload, or public exploit is identified.
Technical impact
An unauthenticated network request can bypass authorization associated with XML Web Publishing and reach an interface that was disabled. The supplied assessment identifies high confidentiality and integrity impact, so unauthorized disclosure or modification is possible. No availability impact is identified in the supplied assessment. The record does not establish the exact data, accounts, operations, or record scope that may be reachable after the bypass.
Business impact
The vulnerability weakens a configuration control intended to disable Custom Web Publishing with XML, allowing a supposedly inaccessible interface to be reached through a specially formed request. If successfully exploited, the organization could face unauthorized disclosure or modification through the XML Web Publishing interface. This may affect the confidentiality and integrity of FileMaker data and warrants review of related requests and changes. The record does not confirm a breach, data disclosure, unauthorized change, or other specific incident.
Remediation
- Upgrade Claris FileMaker Server to
26.0.3, the release identified by the record as addressing the vulnerability. - After updating, verify the deployed release on every server and confirm that the
Web Publishing Engineis no longer running an affected release. - Do not rely on disabling
Custom Web Publishing with XMLas the sole remediation because the vulnerability bypasses that setting. - Review XML-related requests and activity on servers that ran an affected release; if suspicious activity is found, follow the organization’s incident-response process.
Detection
- Inventory Claris FileMaker Server deployments and identify systems that run or expose the
Web Publishing Engine. - Check the running release on each server and compare it with the affected and addressed boundaries in the record.
- Review the
Custom Web Publishing with XMLsetting, but do not treat the disabled setting alone as proof of safety because the vulnerability bypasses that control. - Where request logging is available, review requests reaching the
XML Web Publishing interfaceand requests containing anextended privilege header. - Preserve relevant request metadata for unauthorized-access review. The record does not provide an exact header format or specific IOC, so the absence of matching log evidence does not prove that a system was not exposed.