Hikvision camera firmware input validation flaw exposes partial sensitive data

Note: This data is for reference and cybersecurity research purposes only.CyStack advises users not to use this information for unlawful purposes.

Overview

Original source data

Insufficient validation of input parameters in the firmware of some Hikvision cameras allows unauthenticated attackers to retrieve partial sensitive data.

Affected products and scope

  • Hikvision DS-2CD Series: recorded as affected.
  • Hikvision DS-2DE Series: recorded as affected.
  • Hikvision DS-2DP Series: recorded as affected.
  • Hikvision DS-2TD Series: recorded as affected.

The record uses Hikvision's security firmware download page as the version reference for each series rather than providing numeric firmware boundaries. No exact affected build, fixed build, or parallel branch status is established.

Technical details

The affected component is camera firmware, and the weakness is classified as CWE-20, Improper Input Validation. The firmware does not sufficiently validate attacker-controlled input parameters, which can allow an unauthenticated network attacker to trigger disclosure of partial sensitive data. The supplied attack characteristics indicate low attack complexity, no privileges, and no user interaction. Public details do not identify the request endpoint, parameter names, protocol, or internal code path, so those implementation details remain unknown. The affected scope covers the four listed Hikvision camera series, but no exact affected firmware builds are established.

Exploitability

  • Reachability: network based.
  • Access: no authentication or privileges are required, and no user interaction is required.
  • Complexity: low according to the supplied attack characteristics.
  • Status: the supplied record does not identify a public exploit and does not mark the vulnerability as known exploited; the consulted GCVE data records exploitation as none and automatable as yes.

The absence of public exploitation information in the record does not prove that every deployment is safe or that future exploitation will not occur.

Technical impact

The confirmed technical outcome is a confidentiality impact limited to partial sensitive data retrieval; integrity and availability impact are not identified in the record. Because authentication is not required, an exposed camera may be queried by an attacker who can reach its network service. The exact data categories, including whether the disclosure involves credentials, configuration, media, or other information, are unknown, so practical exposure must be assessed per deployment. Possible organisational consequences include disclosure of camera or environmental information and increased privacy or security risk. The record does not establish a breach or broader compromise.

Business impact

An affected camera may disclose partial sensitive data to an unauthenticated remote party, creating a confidentiality and privacy concern. This could increase risk to systems or locations monitored by the camera, but the record does not identify the data fields or show that any particular deployment was compromised. Operations teams should prioritize inventory and model-specific firmware review for devices in the four affected series, especially where the devices are reachable from broad network segments. Impact on service availability and data integrity is not established.

Remediation

  1. Inventory every Hikvision camera in the DS-2CD, DS-2DE, DS-2DP, and DS-2TD series, including its model identifier, serial number, and installed firmware.
  2. Use Hikvision's security firmware download service to query the specific model or serial number and apply the firmware that the vendor identifies for that device. The available record does not provide an exact fixed release, so do not infer one from a generic latest firmware label.
  3. For batch upgrades, use Hikvision Delivery Assistant, which Hikvision recommends for camera firmware upgrades.
  4. Review Hikvision's Security Camera Deployment Guide and apply the deployment controls appropriate to the installation.
  5. If model-specific firmware status cannot be confirmed, record the device as unresolved rather than treating it as unaffected.

Detection

  1. Build an inventory of all cameras in the DS-2CD, DS-2DE, DS-2DP, and DS-2TD series, recording the model, serial number, and installed firmware.
  2. Use Hikvision's security firmware download service to query by serial number or model, then compare the installed firmware with the device-specific affected versions and available remediation firmware.
  3. Review network telemetry for unexpected unauthenticated access to camera services and requests containing abnormal input parameters. Treat this as precautionary monitoring, not a known IOC, because the advisory does not define an endpoint or log signature.
  4. Investigate unexplained access to or disclosure of camera data in connection with inbound network activity. Do not treat the absence of suspicious logs as proof of safety.
  5. After upgrading, recheck the reported firmware and retain evidence of model-specific remediation.
Sources (10)
Learn more

Run an in-depth assessment with complete web risk management

CyStack VulnScan continuously discovers assets, validates vulnerabilities, and helps security teams prioritize remediation across the organization.