Remote buffer overflow in Tenda AC7 and AC18

Note: This data is for reference and cybersecurity research purposes only.CyStack advises users not to use this information for unlawful purposes.

What is CVE-2025-9023?

CVE-2025-9023 is a vulnerability classified as Buffer Copy without Checking Size of Input and Improper Restriction of Operations within the Bounds of a Memory Buffer, affecting AC7 (affected versions: 15.03.05.19 and 15.03.06.44) and AC18 (affected versions: 15.03.05.19 and 15.03.06.44). This vulnerability is rated High, with a CVSS score of 8.7. Public exploit code or evidence is available for this vulnerability, but that does not confirm exploitation in the wild.

Overview

Original source data

A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Affected products and scope

  • Tenda AC7: version 15.03.05.19 is affected; version 15.03.06.44 is affected.
  • Tenda AC18: version 15.03.05.19 is affected; version 15.03.06.44 is affected.
  • The record does not provide a fixed version. The status of other branches or versions is unknown and should not be inferred to be safe.

Technical details

The flaw is located in the formSetSchedLed function of the web management endpoint /goform/SetLEDCfg. The attacker-controlled Time argument is processed without adequate length validation before being copied into a bounded buffer, causing a buffer overflow and memory corruption. An attacker must deliver crafted input to a management interface reachable over the network; however, the specific HTTP method and authentication requirement are not established consistently across the available sources. The evidence does not identify the buffer size, copy routine, memory layout, or the precise conditions required to progress from memory corruption to code execution.

Exploitability

  • The flaw is remotely reachable through the router's network management interface.
  • An exploit or proof-of-concept has been publicly disclosed, and the CNA source states that technical details are publicly known.
  • Exploit complexity is described as low in the supplied data, but the authentication requirement is unresolved: the normalized record indicates that low privileges are required, while the CNA analysis describes unauthenticated access. Treat pre-authentication exploitation as unconfirmed until the deployed configuration is verified.
  • The record confirms public exploit availability but does not establish widespread real-world exploitation.

Technical impact

The memory corruption occurs while the router processes a request for LED configuration. Direct effects may include service crashes or reboots, while successful exploitation could alter device data or behavior and, depending on the exploit conditions, enable code execution. The record supports impacts to confidentiality, integrity, and availability, but it does not establish the exact post-exploitation privileges, persistence capability, or level of operating-system control. The risk of router compromise is therefore significant, while the precise post-exploitation consequences remain subject to verification.

Business impact

  • Successful exploitation could destabilize the router, cause reboots, or interrupt network services.
  • Memory corruption may affect the confidentiality, integrity, and availability of data or functions handled by the router.
  • If exploitation provides broader control, an attacker could alter the device's network behavior, such as routing or management policy; that specific capability is not established by the record.
  • Exposure of the management endpoint to untrusted networks increases the reachable attack surface for the public exploit.

Remediation

  1. Identify devices running 15.03.05.19 or 15.03.06.44 and apply a Tenda firmware release if Tenda confirms that it fixes this issue. The record and consulted CNA source do not identify a specific fixed version.
  2. Until a confirmed fix is available, restrict the web management interface to a trusted administration network and block direct Internet access with firewall rules or ACLs.
  3. If a device cannot be updated or safely isolated, consider replacing it with a supported alternative. The CNA source states that no specific countermeasure is currently known.
  4. Use strong administrative credentials and segment the router from important internal systems. These measures reduce exposure but do not patch the buffer overflow.

Detection

  • Inventory Tenda AC7 and AC18 devices and compare their firmware against the affected versions listed in affected_summary.
  • Determine whether each device's web management interface is reachable from the Internet or other untrusted networks.
  • Review available web or firewall logs for requests to /goform/SetLEDCfg, with particular attention to unusual Time values. This is precautionary monitoring, not a confirmed indicator of compromise.
  • Investigate crashes, unexpected reboots, management-service failures, or configuration changes following anomalous requests to the endpoint.
  • The absence of suspicious requests or log entries does not prove that a device is safe.
Sources (16)
Learn more

Run an in-depth assessment with complete web risk management

CyStack VulnScan continuously discovers assets, validates vulnerabilities, and helps security teams prioritize remediation across the organization.